DIAGNOSTIC VALUE OF CORONARY TRANSLUMINAL ATTENUATION GRADIENT IN CORONARY CT ANGIOGRAPHY FOR DETERMINING STENOSIS SEVERITY

Authors

1 Medical University of Isfahan

2 University of Esfahan

3 Uninersity of Isfahan Medical Sciences

10.22034/icrj.2019.100893

Abstract

Abstract Background:
The purpose of the present study was to determine the
diagnostic accuracy ofTransluminal attenuation gradient (TAG) in 64-slice  multislice  computed  tomography in the detection of significant coronary artery disease, using diameter stenosis as the comparison. Methods:
In 82 patients scheduled for coronary CTangiography, 64-slice MSCT was performed and evaluated for the presence of significant (>50% luminal narrowing) stenosis. Then TAG determined from the change in HU per 5-mm length of coronary artery and defined as the linear regression coefficient between intra-HU and length from the ostium (millimeters).
 
Result:
Total mean (S.E) of TAG is -2.87(0.28), the TAG is significantly different (PV<0.0001) in patients with significant stenosis -4.71(0.36) in compare with nonsignificant stenosis -1.30(0.23). Also we definition the cutoff point for TAG for better evaluation of severity.
 
Conclusion:
The present study confirms that TAG is the accurate and noninvasive functional method to determine the significant coronary artery stenosis.